RFC1316-MIB DEFINITIONS ::= BEGIN
 
        IMPORTS
                Counter, TimeTicks, Gauge
                        FROM RFC1155-SMI
                DisplayString, mib-2
                        FROM RFC1213-MIB
                OBJECT-TYPE
                        FROM RFC-1212;
 
-- this is the MIB module for character stream devices
 
char    OBJECT IDENTIFIER ::= { mib-2 19 }
 
-- Textual Conventions
 
    AutonomousType    ::= OBJECT IDENTIFIER
 
-- The object identifier is an independently extensible type
-- identification value.  It may, for example indicate a
-- particular sub-tree with further MIB definitions, or
-- define something like a protocol type or type of
-- hardware.
 
    InstancePointer   ::= OBJECT IDENTIFIER
 
-- The object identifier is a pointer to a specific instance
-- of a MIB object in this agent's implemented MIB.  By
-- convention, it is the first object in the conceptual row
-- for the instance.
 
-- the generic Character group
 
-- Implementation of this group is mandatory for all
-- systems that offer character ports
 
charNumber OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of entries in charPortTable, regardless
        of their current state."
    ::= { char 1 }
 
 
-- the Character Port table
 
charPortTable OBJECT-TYPE
    SYNTAX SEQUENCE OF CharPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "A list of port entries.  The number of entries is
        given by the value of charNumber."
    ::= { char 2 }
 
charPortEntry OBJECT-TYPE
    SYNTAX CharPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Status and parameter values for a character port."
    INDEX { charPortIndex }
    ::= { charPortTable 1 }
 
CharPortEntry ::=
    SEQUENCE {
        charPortIndex
            INTEGER,
        charPortName
            DisplayString,
        charPortType
            INTEGER,
        charPortHardware
            AutonomousType,
        charPortReset
            INTEGER,
        charPortAdminStatus
            INTEGER,
        charPortOperStatus
            INTEGER,
        charPortLastChange
            TimeTicks,
        charPortInFlowType
            INTEGER,
        charPortOutFlowType
            INTEGER,
        charPortInFlowState
            INTEGER,
        charPortOutFlowState
            INTEGER,
        charPortInCharacters
            Counter,
        charPortOutCharacters
            Counter,
        charPortAdminOrigin
            INTEGER,
        charPortSessionMaximum
            INTEGER,
        charPortSessionNumber
            Gauge,
        charPortSessionIndex
            INTEGER
    }
 
charPortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "A unique value for each character port.  Its value
        ranges between 1 and the value of charNumber.  By
        convention and if possible, hardware port numbers
        come first, with a simple, direct mapping.  The
        value for each port must remain constant at least
        from one re-initialization of the network management
        agent to the next."
    ::= { charPortEntry 1 }
 
charPortName OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..32))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "An administratively assigned name for the port,
        typically with some local significance."
    ::= { charPortEntry 2 }
 
charPortType OBJECT-TYPE
    SYNTAX INTEGER { physical(1), virtual(2) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The port's type, 'physical' if the port represents
        an external hardware connector, 'virtual' if it does
        not."
    ::= { charPortEntry 3 }
 
charPortHardware OBJECT-TYPE
    SYNTAX AutonomousType
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "A reference to hardware MIB definitions specific to
        a physical port's external connector.  For example,
        if the connector is RS-232, then the value of this
        object refers to a MIB sub-tree defining objects
        specific to RS-232.  If an agent is not configured
        to have such values, the agent returns the object
        identifier:
 
            nullHardware OBJECT IDENTIFIER ::= { 0 0 }
        "
    ::= { charPortEntry 4 }
 
charPortReset OBJECT-TYPE
    SYNTAX INTEGER { ready(1), execute(2) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "A control to force the port into a clean, initial
        state, both hardware and software, disconnecting all
        the port's existing sessions.  In response to a
        get-request or get-next-request, the agent always
        returns 'ready' as the value.  Setting the value to
        'execute' causes a reset."
    ::= { charPortEntry 5 }
 
charPortAdminStatus OBJECT-TYPE
    SYNTAX INTEGER { enabled(1), disabled(2), off(3),
                     maintenance(4) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The port's desired state, independent of flow
        control.  'enabled' indicates that the port is
        allowed to pass characters and form new sessions.
        'disabled' indicates that the port is allowed to
        pass characters but not form new sessions.  'off'
        indicates that the port is not allowed to pass
        characters or have any sessions. 'maintenance'
        indicates a maintenance mode, exclusive of normal
        operation, such as running a test."
    ::= { charPortEntry 6 }
 
charPortOperStatus OBJECT-TYPE
    SYNTAX INTEGER { up(1), down(2),
                     maintenance(3), absent(4), active(5) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The port's actual, operational state, independent
        of flow control.  'up' indicates able to function
        normally.  'down' indicates inability to function
        for administrative or operational reasons.
        'maintenance' indicates a maintenance mode,
        exclusive of normal operation, such as running a
        test.  'absent' indicates that port hardware is not
        present.  'active' indicates up with a user present
        (e.g. logged in)."
    ::= { charPortEntry 7 }
 
charPortLastChange OBJECT-TYPE
    SYNTAX TimeTicks
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The value of sysUpTime at the time the port entered
        its current operational state.  If the current state
        was entered prior to the last reinitialization of
        the local network management subsystem, then this
        object contains a zero value."
    ::= { charPortEntry 8 }
 
charPortInFlowType OBJECT-TYPE
    SYNTAX INTEGER { none(1), xonXoff(2), hardware(3),
                     ctsRts(4), dsrDtr(5) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The port's type of input flow control.  'none'
        indicates no flow control at this level or below.
        'xonXoff' indicates software flow control by
        recognizing XON and XOFF characters.  'hardware'
        indicates flow control delegated to the lower level,
        for example a parallel port.
 
        'ctsRts' and 'dsrDtr' are specific to RS-232-like
        ports.  Although not architecturally pure, they are
        included here for simplicity's sake."
    ::= { charPortEntry 9 }
 
charPortOutFlowType OBJECT-TYPE
    SYNTAX INTEGER { none(1), xonXoff(2), hardware(3),
                     ctsRts(4), dsrDtr(5) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The port's type of output flow control.  'none'
        indicates no flow control at this level or below.
        'xonXoff' indicates software flow control by
        recognizing XON and XOFF characters.  'hardware'
        indicates flow control delegated to the lower level,
        for example a parallel port.
 
        'ctsRts' and 'dsrDtr' are specific to RS-232-like
        ports.  Although not architecturally pure, they are
        included here for simplicy's sake."
    ::= { charPortEntry 10 }
 
charPortInFlowState OBJECT-TYPE
    SYNTAX INTEGER { none(1), unknown(2), stop(3), go(4) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The current operational state of input flow control
        on the port.  'none' indicates not applicable.
        'unknown' indicates this level does not know.
        'stop' indicates flow not allowed.  'go' indicates
        flow allowed."
    ::= { charPortEntry 11 }
 
charPortOutFlowState OBJECT-TYPE
    SYNTAX INTEGER { none(1), unknown(2), stop(3), go(4) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The current operational state of output flow
        control on the port.  'none' indicates not
        applicable.  'unknown' indicates this level does not
        know.  'stop' indicates flow not allowed.  'go'
        indicates flow allowed."
    ::= { charPortEntry 12 }
 
charPortInCharacters OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Total number of characters detected as input from
        the port since system re-initialization and while
        the port operational state was 'up', 'active', or
        'maintenance', including, for example, framing, flow
        control (i.e. XON and XOFF), each occurrence of a
        BREAK condition, locally-processed input, and input
        sent to all sessions."
    ::= { charPortEntry 13 }
 
charPortOutCharacters OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Total number of characters detected as output to
        the port since system re-initialization and while
        the port operational state was 'up', 'active', or
        'maintenance', including, for example, framing, flow
        control (i.e. XON and XOFF), each occurrence of a
        BREAK condition, locally-created output, and output
        received from all sessions."
    ::= { charPortEntry 14 }
 
charPortAdminOrigin OBJECT-TYPE
    SYNTAX INTEGER { dynamic(1), network(2), local(3),
                     none(4) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The administratively allowed origin for
        establishing session on the port.  'dynamic' allows
        'network' or 'local' session establishment. 'none'
        disallows session establishment."
    ::= { charPortEntry 15 }
 
charPortSessionMaximum OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The maximum number of concurrent sessions allowed
        on the port.  A value of -1 indicates no maximum.
        Setting the maximum to less than the current number
        of sessions has unspecified results."
    ::= { charPortEntry 16 }
 
charPortSessionNumber OBJECT-TYPE
    SYNTAX Gauge
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of open sessions on the port that are in
        the connecting, connected, or disconnecting state."
    ::= { charPortEntry 17 }
 
charPortSessionIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The value of charSessIndex for the port's first or
        only active session.  If the port has no active
        session, the agent returns the value zero."
    ::= { charPortEntry 18 }
 
 
-- the Character Session table
 
charSessTable OBJECT-TYPE
    SYNTAX SEQUENCE OF CharSessEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "A list of port session entries."
    ::= { char 3 }
 
charSessEntry OBJECT-TYPE
    SYNTAX CharSessEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Status and parameter values for a character port
        session."
    INDEX { charSessPortIndex, charSessIndex }
    ::= { charSessTable 1 }
 
CharSessEntry ::=
    SEQUENCE {
        charSessPortIndex
            INTEGER,
        charSessIndex
            INTEGER,
        charSessKill
            INTEGER,
        charSessState
            INTEGER,
        charSessProtocol
            AutonomousType,
        charSessOperOrigin
            INTEGER,
        charSessInCharacters
            Counter,
        charSessOutCharacters
            Counter,
        charSessConnectionId
            InstancePointer,
        charSessStartTime
            TimeTicks
    }
 
charSessPortIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The value of charPortIndex for the port to which
        this session belongs."
    ::= { charSessEntry 1 }
 
charSessIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The session index in the context of the port, a
        non-zero positive integer.  Session indexes within a
        port need not be sequential.  Session indexes may be
        reused for different ports.  For example, port 1 and
        port 3 may both have a session 2 at the same time.
        Session indexes may have any valid integer value,
        with any meaning convenient to the agent
        implementation."
    ::= { charSessEntry 2 }
 
charSessKill OBJECT-TYPE
    SYNTAX INTEGER { ready(1), execute(2) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "A control to terminate the session.  In response to
        a get-request or get-next-request, the agent always
        returns 'ready' as the value.  Setting the value to
        'execute' causes termination."
    ::= { charSessEntry 3 }
 
charSessState OBJECT-TYPE
    SYNTAX INTEGER { connecting(1), connected(2),
                     disconnecting(3) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The current operational state of the session,
        disregarding flow control.  'connected' indicates
        that character data could flow on the network side
        of session.  'connecting' indicates moving from
        nonexistent toward 'connected'.  'disconnecting'
        indicates moving from 'connected' or 'connecting' to
        nonexistent."
    ::= { charSessEntry 4 }
 
charSessProtocol OBJECT-TYPE
    SYNTAX AutonomousType
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The network protocol over which the session is
        running.  Other OBJECT IDENTIFIER values may be
        defined elsewhere, in association with specific
        protocols.  However, this document assigns those of
        known interest as of this writing."
    ::= { charSessEntry 5 }
 
wellKnownProtocols OBJECT IDENTIFIER ::= { char 4 }
 
protocolOther  OBJECT IDENTIFIER ::= {wellKnownProtocols 1}
protocolTelnet OBJECT IDENTIFIER ::= {wellKnownProtocols 2}
protocolRlogin OBJECT IDENTIFIER ::= {wellKnownProtocols 3}
protocolLat    OBJECT IDENTIFIER ::= {wellKnownProtocols 4}
protocolX29    OBJECT IDENTIFIER ::= {wellKnownProtocols 5}
protocolVtp    OBJECT IDENTIFIER ::= {wellKnownProtocols 6}
 
charSessOperOrigin OBJECT-TYPE
    SYNTAX INTEGER { unknown(1), network(2), local(3) }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The session's source of establishment."
    ::= { charSessEntry 6 }
 
charSessInCharacters OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This session's subset of charPortInCharacters."
    ::= { charSessEntry 7 }
 
charSessOutCharacters OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This session's subset of charPortOutCharacters."
    ::= { charSessEntry 8 }
 
charSessConnectionId OBJECT-TYPE
    SYNTAX InstancePointer
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "A reference to additional local MIB information.
        This should be the highest available related MIB,
        corresponding to charSessProtocol, such as Telnet.
        For example, the value for a TCP connection (in the
        absence of a Telnet MIB) is the object identifier of
        tcpConnState.  If an agent is not configured to have
        such values, the agent returns the object
        identifier:
 
            nullConnectionId OBJECT IDENTIFIER ::= { 0 0 }
        "
    ::= { charSessEntry 9 }
 
charSessStartTime OBJECT-TYPE
    SYNTAX TimeTicks
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The value of sysUpTime in MIB-2 when the session
        entered connecting state."
    ::= { charSessEntry 10 }
 
END