RFC1285-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI transmission FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in [7]. -- this is the FDDI MIB module fddi OBJECT IDENTIFIER ::= { transmission 15 } -- textual conventions FddiTime ::= INTEGER (0..2147483647) -- This data type specifies octet units of 80 nanoseconds as -- an integer value. It is used for Path Latency and -- Synchronous Bandwidth values. The encoding is normal -- integer representation (not twos complement). FddiResourceId ::= INTEGER (0..65535) -- This data type is used to refer to an instance of a MAC, -- PORT, PATH, or ATTACHMENT Resource ID. Indexing begins -- at 1. Zero is used to indicate the absence of a resource. FddiSMTStationIdType ::= OCTET STRING (SIZE (8)) -- The unique identifier for the FDDI station. This is a -- string of 8 octets, represented as -- X' yy yy xx xx xx xx xx xx' -- with the low order 6 octet (xx) from a unique IEEE -- assigned address. The high order two bits of the IEEE -- address, the group address bit and the administration bit -- (Universal/Local) bit should both be zero. The first two -- octets, the yy octets, are implementor-defined. -- -- The representation of the address portion of the station id -- is in the IEEE (ANSI/IEEE P802.1A) canonical notation for -- 48 bit addresses. The canonical form is a 6-octet string -- where the first octet contains the first 8 bits of the -- address, with the I/G(Individual/Group) address bit as the -- least significant bit and the U/L (Universal/Local) bit -- as the next more significant bit, and so on. Note that -- addresses in the ANSI FDDI standard SMT frames are -- represented in FDDI MAC order. FddiMACLongAddressType ::= OCTET STRING (SIZE (6)) -- The representation of long MAC addresses as management -- values is in the IEEE (ANSI/IEEE P802.1A) canonical -- notation for 48 bit addresses. The canonical form is a -- 6-octet string where the first octet contains the first 8 -- bits of the address, with the I/G (Individual/Group) -- address bit as the least significant bit and the U/L -- (Universal/Local) bit as the next more significant bit, -- and so on. Note that the addresses in the SMT frames are -- represented in FDDI MAC order. -- groups in the FDDI MIB module snmpFddiSMT OBJECT IDENTIFIER ::= { fddi 1 } snmpFddiMAC OBJECT IDENTIFIER ::= { fddi 2 } snmpFddiPATH OBJECT IDENTIFIER ::= { fddi 3 } snmpFddiPORT OBJECT IDENTIFIER ::= { fddi 4 } snmpFddiATTACHMENT OBJECT IDENTIFIER ::= { fddi 5 } snmpFddiChipSets OBJECT IDENTIFIER ::= { fddi 6 } -- the SMT group -- Implementation of the SMT group is mandatory for all -- systems which implement manageable FDDI subsystems. snmpFddiSMTNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The number of SMT implementations (regardless of their current state) on this network management application entity. The value for this variable must remain constant at least from one re- initialization of the entity's network management system to the next re-initialization." ::= { snmpFddiSMT 1 } -- the SMT table snmpFddiSMTTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpFddiSMTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of SMT entries. The number of entries is given by the value of snmpFddiSMTNumber." ::= { snmpFddiSMT 2 } snmpFddiSMTEntry OBJECT-TYPE SYNTAX SnmpFddiSMTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An SMT entry containing information common to a given SMT." INDEX { snmpFddiSMTIndex } ::= { snmpFddiSMTTable 1 } SnmpFddiSMTEntry ::= SEQUENCE { snmpFddiSMTIndex INTEGER, snmpFddiSMTStationId FddiSMTStationIdType, snmpFddiSMTOpVersionId INTEGER, snmpFddiSMTHiVersionId INTEGER, snmpFddiSMTLoVersionId INTEGER, snmpFddiSMTMACCt INTEGER, snmpFddiSMTNonMasterCt INTEGER, snmpFddiSMTMasterCt INTEGER, snmpFddiSMTPathsAvailable INTEGER, snmpFddiSMTConfigCapabilities INTEGER, snmpFddiSMTConfigPolicy INTEGER, snmpFddiSMTConnectionPolicy INTEGER, snmpFddiSMTTNotify INTEGER, snmpFddiSMTStatusReporting INTEGER, snmpFddiSMTECMState INTEGER, snmpFddiSMTCFState INTEGER, snmpFddiSMTHoldState INTEGER, snmpFddiSMTRemoteDisconnectFlag INTEGER, snmpFddiSMTStationAction INTEGER } snmpFddiSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { snmpFddiSMTEntry 1 } snmpFddiSMTStationId OBJECT-TYPE SYNTAX FddiSMTStationIdType -- OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "Uniquely identifies an FDDI station." REFERENCE "ANSI { fddiSMT 11 }" ::= { snmpFddiSMTEntry 2 } snmpFddiSMTOpVersionId OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The version that this station is using for its operation (refer to ANSI 7.1.2.2)." REFERENCE "ANSI { fddiSMT 13 }" ::= { snmpFddiSMTEntry 3 } snmpFddiSMTHiVersionId OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The highest version of SMT that this station supports (refer to ANSI 7.1.2.2)." REFERENCE "ANSI { fddiSMT 14 }" ::= { snmpFddiSMTEntry 4 } snmpFddiSMTLoVersionId OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The lowest version of SMT that this station supports (refer to ANSI 7.1.2.2)." REFERENCE "ANSI { fddiSMT 15 }" ::= { snmpFddiSMTEntry 5 } snmpFddiSMTMACCt OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of MACs in the station or concentrator." REFERENCE "ANSI { fddiSMT 21 }" ::= { snmpFddiSMTEntry 6 } snmpFddiSMTNonMasterCt OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Non Master PORTs (A, B, or S PORTs) in the station or concentrator." REFERENCE "ANSI { fddiSMT 22 }" ::= { snmpFddiSMTEntry 7 } snmpFddiSMTMasterCt OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Master PORTs in a node. If the node is not a concentrator, the value is zero." REFERENCE "ANSI { fddiSMT 23 }" ::= { snmpFddiSMTEntry 8 } snmpFddiSMTPathsAvailable OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates the PATH types available in the station. The value is a sum. This value initially takes the value zero, then for each type of PATH that this node has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 For example, a station having Primary and Local PATHs available would have a value of 5 (2**0 + 2**2)." REFERENCE "ANSI { fddiSMT 24 }" ::= { snmpFddiSMTEntry 9 } snmpFddiSMTConfigCapabilities OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates capabilities that are present in the node. If 'holdAvailable' is present, this indicates support of the optional Hold Function (refer to ANSI SMT 9.4.3.2). If 'CF-Wrap-AB' is present, this indicates that the WRAP_AB state is forced. The value is a sum. This value initially takes the value zero, then for each of the configuration policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power holdAvailable 0 CF-Wrap-AB 1 " REFERENCE "ANSI { fddiSMT 25 }" ::= { snmpFddiSMTEntry 10 } snmpFddiSMTConfigPolicy OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the configuration policies currently enforced in the node (refer to ANSI SMT 9.4.3.2). The 'configurationHold' policy refers to the Hold flag, and should not be present only if the Hold function is supported. The 'CF-Wrap- AB' policy refers to the CF_Wrap_AB flag. The value is a sum. This value initially takes the value zero, then for each of the configuration policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power configurationHold 0 CF-Wrap-AB 1 " REFERENCE "ANSI { fddiSMT 26 }" ::= { snmpFddiSMTEntry 11 } snmpFddiSMTConnectionPolicy OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the connection policies enforced at the station. A station sets the corresponding policy for each of the connection types that it rejects. The letter designations, X and Y, in the 'rejectX-Y' names have the following significance: X represents the PC-Type of the local PORT and Y represents a PC-Neighbor in the evaluation of Connection-Policy (PC-Type, PC- Neighbor) that is done to determine the setting of T-Val(3) in the PC-Signaling sequence (refer to ANSI Section 9.6.3). The value is a sum. This value initially takes the value zero, then for each of the connection policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power rejectA-A 0 rejectA-B 1 rejectA-S 2 rejectA-M 3 rejectB-A 4 rejectB-B 5 rejectB-S 6 rejectB-M 7 rejectS-A 8 rejectS-B 9 rejectS-S 10 rejectS-M 11 rejectM-A 12 rejectM-B 13 rejectM-S 14 rejectM-M 15 Implementors should note that the polarity of these bits is different in different places in an SMT system. Implementors should take appropriate care." REFERENCE "ANSI { fddiSMT 27 }" ::= { snmpFddiSMTEntry 12 } snmpFddiSMTTNotify OBJECT-TYPE SYNTAX INTEGER (2..30) ACCESS read-write STATUS mandatory DESCRIPTION "The timer used in the Neighbor Notification protocol, reported in seconds and ranging from 2 to 30 seconds (refer to ANSI SMT 8.3.1)." REFERENCE "ANSI { fddiSMT 29 }" ::= { snmpFddiSMTEntry 13 } snmpFddiSMTStatusReporting OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the node implements the Status Reporting Protocol. This object is included for compatibility with products that were designed prior to the adoption of this standard." REFERENCE "ANSI { fddiSMT 30 }" ::= { snmpFddiSMTEntry 14 } snmpFddiSMTECMState OBJECT-TYPE SYNTAX INTEGER { ec0(1), -- Out ec1(2), -- In ec2(3), -- Trace ec3(4), -- Leave ec4(5), -- Path_Test ec5(6), -- Insert ec6(7), -- Check ec7(8) -- Deinsert } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current state of the ECM state machine (refer to ANSI SMT 9.5.2)." REFERENCE "ANSI { fddiSMT 41 }" ::= { snmpFddiSMTEntry 15 } snmpFddiSMTCFState OBJECT-TYPE SYNTAX INTEGER { cf0(1), -- Isolated cf1(2), -- Wrap_S cf2(3), -- Wrap_A cf3(4), -- Wrap_B cf4(5), -- Wrap_AB cf5(6) -- Thru } ACCESS read-only STATUS mandatory DESCRIPTION "The attachment configuration for the station or concentrator (refer to ANSI SMT 9.7.4.3)." REFERENCE "ANSI { fddiSMT 42 }" ::= { snmpFddiSMTEntry 16 } snmpFddiSMTHoldState OBJECT-TYPE SYNTAX INTEGER { not-implemented(1), -- holding not implemented not-holding(2), holding-prm(3), -- holding on primary holding-sec(4) -- holding on secondary } ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates the current state of the Hold function. The values are determined as follows: 'holding-prm' is set if the primary ring is operational and the Recovery Enable Flag is clear (NOT NO_Flag(primary) AND NOT RE_Flag). is set if the secondary ring is operational and the Recovery Enable Flag is clear (NOT NO_Flag(secondary) AND NOT RE_Flag). Ref 9.4.3. and 10.3.1. the primary or secondary, i.e., the Recovery Enable, RE_Flag, is set." REFERENCE "ANSI { fddiSMT 43 }" ::= { snmpFddiSMTEntry 17 } snmpFddiSMTRemoteDisconnectFlag OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag indicating that the station was remotely disconnected from the network. A station requires a Connect Action (SM_CM_CONNECT.request (Connect)) to rejoin and clear the flag (refer to ANSI 6.4.5.2)." REFERENCE "ANSI { fddiSMT 44 }" ::= { snmpFddiSMTEntry 18 } snmpFddiSMTStationAction OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following connect(2), disconnect(3), path-Test(4), self-Test(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows: Other: Results in a badValue error. Connect: Generates an SM_CM_Connect.request(connect) signal to CMT indicating that the ECM State machine is to begin a connection sequence. The fddiSMTRemoteDisconnectFlag is cleared on the setting of this variable to 1. See ANSI Ref 9.3.1.1. Disconnect: Generates an SM_CM_Connect.request(disconnect) signal to ECM and sets the fddiSMTRemoteDisconnectFlag. See ANSI Ref 9.3.1.1. Path-Test: Initiates a station path test. The Path_Test variable (See ANSI Ref. 9.4.1) is set to Testing. The results of this action are not specified in this standard. Self-Test: Initiates a station self test. The results of this action are not specified in this standard. Attempts to set this object to all other values results in a badValue error. Agents may elect to return a badValue error on attempts to set this variable to path-Test(4) or self-Test(5)." REFERENCE "ANSI { fddiSMT 60 }" ::= { snmpFddiSMTEntry 19 } -- the MAC group -- Implementation of the MAC Group is mandatory for all -- systems which implement manageable FDDI subsystems. snmpFddiMACNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of MAC implementations (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { snmpFddiMAC 1 } -- the MAC table snmpFddiMACTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpFddiMACEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of MAC entries. The number of entries is given by the value of snmpFddiMACNumber." ::= { snmpFddiMAC 2 } snmpFddiMACEntry OBJECT-TYPE SYNTAX SnmpFddiMACEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A MAC entry containing information common to a given MAC." INDEX { snmpFddiMACSMTIndex, snmpFddiMACIndex } ::= { snmpFddiMACTable 1 } SnmpFddiMACEntry ::= SEQUENCE { snmpFddiMACSMTIndex INTEGER, snmpFddiMACIndex INTEGER, snmpFddiMACFrameStatusCapabilities INTEGER, snmpFddiMACTMaxGreatestLowerBound FddiTime, snmpFddiMACTVXGreatestLowerBound FddiTime, snmpFddiMACPathsAvailable INTEGER, snmpFddiMACCurrentPath INTEGER, snmpFddiMACUpstreamNbr FddiMACLongAddressType, snmpFddiMACOldUpstreamNbr FddiMACLongAddressType, snmpFddiMACDupAddrTest INTEGER, snmpFddiMACPathsRequested INTEGER, snmpFddiMACDownstreamPORTType INTEGER, snmpFddiMACSMTAddress FddiMACLongAddressType, snmpFddiMACTReq FddiTime, snmpFddiMACTNeg FddiTime, snmpFddiMACTMax FddiTime, snmpFddiMACTvxValue FddiTime, snmpFddiMACTMin FddiTime, snmpFddiMACCurrentFrameStatus INTEGER, snmpFddiMACFrameCts Counter, snmpFddiMACErrorCts Counter, snmpFddiMACLostCts Counter, snmpFddiMACFrameErrorThreshold INTEGER, snmpFddiMACFrameErrorRatio INTEGER, snmpFddiMACRMTState INTEGER, snmpFddiMACDaFlag INTEGER, snmpFddiMACUnaDaFlag INTEGER, snmpFddiMACFrameCondition INTEGER, snmpFddiMACChipSet OBJECT IDENTIFIER, snmpFddiMACAction INTEGER } snmpFddiMACSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of the SMT index associated with this MAC." ::= { snmpFddiMACEntry 1 } snmpFddiMACIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each MAC on the managed entity. The MAC identified by a particular value of this index is that identified by the same value of an ifIndex object instance. That is, if a MAC is associated with the interface whose value of ifIndex in the Internet-Standard MIB is equal to 5, then the value of snmpFddiMACIndex shall also equal 5. The value for each MAC must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { snmpFddiMACEntry 2 } snmpFddiMACFrameStatusCapabilities OBJECT-TYPE SYNTAX INTEGER (0..1799) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates the MAC's bridge and end- station capabilities for operating in a bridged FDDI network. The value is a sum. This value initially takes the value zero, then for each capability present, 2 raised to a power is added to the sum. The powers are according to the following table: Capability Power FSC-Type0 0 -- MAC repeats A/C indicators as received on -- copying with the intent to forward. FSC-Type1 1 -- MAC sets C but not A on copying for -- forwarding. FSC-Type2 2 -- MAC resets C and sets A on C set and -- A reset if the frame is not copied and the -- frame was addressed to this MAC FSC-Type0-programmable 8 -- Type0 capability is programmable FSC-Type1-programmable 9 -- Type1 capability is programmable FSC-Type2-programmable 10 -- Type2 capability is programmable " REFERENCE "ANSI { fddiMAC 11 }" ::= { snmpFddiMACEntry 3 } snmpFddiMACTMaxGreatestLowerBound OBJECT-TYPE SYNTAX FddiTime ACCESS read-write STATUS mandatory DESCRIPTION "The greatest lower bound of T_Max supported for this MAC." REFERENCE "ANSI { fddiMAC 13 }" ::= { snmpFddiMACEntry 4 } snmpFddiMACTVXGreatestLowerBound OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The greatest lower bound of TVX supported for this MAC." REFERENCE "ANSI { fddiMAC 14 }" ::= { snmpFddiMACEntry 5 } snmpFddiMACPathsAvailable OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates the PATH types available for this MAC. The value is a sum. This value initially takes the value zero, then for each type of PATH that this MAC has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 " REFERENCE "ANSI { fddiMAC 22 }" ::= { snmpFddiMACEntry 6 } snmpFddiMACCurrentPath OBJECT-TYPE SYNTAX INTEGER { unknown(1), primary(2), secondary(4), local(8), isolated(16) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the association of the MAC with a station PATH." REFERENCE "ANSI { fddiMAC 23 }" ::= { snmpFddiMACEntry 7 } snmpFddiMACUpstreamNbr OBJECT-TYPE SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The MAC's upstream neighbor's long individual MAC address. It may be determined by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1). The value shall be reported as '00 00 00 00 00 00' if it is unknown." REFERENCE "ANSI { fddiMAC 24 }" ::= { snmpFddiMACEntry 8 } snmpFddiMACOldUpstreamNbr OBJECT-TYPE SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The previous value of the MAC's upstream neighbor's long individual MAC address. It may be determined by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1). The value shall be reported as '00 00 00 00 00 00' if it is unknown." REFERENCE "ANSI { fddiMAC 26 }" ::= { snmpFddiMACEntry 9 } snmpFddiMACDupAddrTest OBJECT-TYPE SYNTAX INTEGER { none(1), pass(2), fail(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The Duplicate Address Test flag, Dup_Addr_Test (refer to ANSI 8.3.1)." REFERENCE "ANSI { fddiMAC 29 }" ::= { snmpFddiMACEntry 10 } snmpFddiMACPathsRequested OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates PATH(s) desired for this MAC. The value is a sum which represents the individual PATHs that are desired. This value initially takes the value zero, then for each type of PATH that this node is, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 Isolated 3 The precedence order is primary, secondary, local, and then isolated if multiple PATHs are desired are set." REFERENCE "ANSI { fddiMAC 32 }" ::= { snmpFddiMACEntry 11 } snmpFddiMACDownstreamPORTType OBJECT-TYPE SYNTAX INTEGER { a(1), b(2), s(3), m(4), unknown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the PC-Type of the first port that is downstream of this MAC (the exit port)." REFERENCE "ANSI { fddiMAC 33 }" ::= { snmpFddiMACEntry 12 } snmpFddiMACSMTAddress OBJECT-TYPE SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The 48 bit individual address of the MAC used for SMT frames." REFERENCE "ANSI { fddiMAC 41 }" ::= { snmpFddiMACEntry 13 } snmpFddiMACTReq OBJECT-TYPE SYNTAX FddiTime ACCESS read-write STATUS mandatory DESCRIPTION "The value of T-Req (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCE "ANSI { fddiMAC 51 }" ::= { snmpFddiMACEntry 14 } snmpFddiMACTNeg OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of T-Neg (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCE "ANSI { fddiMAC 52 }" ::= { snmpFddiMACEntry 15 } snmpFddiMACTMax OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of T-Max (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCE "ANSI { fddiMAC 53 }" ::= { snmpFddiMACEntry 16 } snmpFddiMACTvxValue OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of TvxValue (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCE "ANSI { fddiMAC 54 }" ::= { snmpFddiMACEntry 17 } snmpFddiMACTMin OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "The value of T-Min (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2)." REFERENCE "ANSI { fddiMAC 55 }" ::= { snmpFddiMACEntry 18 } snmpFddiMACCurrentFrameStatus OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the MAC's operational frame status setting functionality. The value is a sum. This value initially takes the value zero, then for each functionality present, 2 raised to a power is added to the sum. The powers are according to the following table: Functionality Power FSC-Type0 0 -- MAC repeats A/C indicators as received FSC-Type1 1 -- MAC sets C but not A on copying for -- forwarding FSC-Type2 2 -- MAC resets C and sets A on C set and A -- reset if frame is not copied " REFERENCE "ANSI { fddiMAC 63 }" ::= { snmpFddiMACEntry 19 } snmpFddiMACFrameCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Frame_Ct (refer to ANSI MAC 2.2.1)." REFERENCE "ANSI { fddiMAC 71 }" ::= { snmpFddiMACEntry 20 } snmpFddiMACErrorCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Error_Ct (refer to ANSI MAC 2.2.1)." REFERENCE "ANSI { fddiMAC 81 }" ::= { snmpFddiMACEntry 21 } snmpFddiMACLostCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Lost_Ct (refer to ANSI MAC 2.2.1)." REFERENCE "ANSI { fddiMAC 82 }" ::= { snmpFddiMACEntry 22 } snmpFddiMACFrameErrorThreshold OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A threshold for determining when a MAC Condition report should be generated. The condition is true when the ratio, ((delta snmpFddiMACLostCt + delta snmpFddiMACErrorCt) / (delta snmpFddiMACFrameCt + delta snmpFddiMACLostCt)) x 2**16. exceeds the threshold. It is used to determine when a station has an unacceptable frame error threshold. The sampling algorithm is implementation dependent. Any attempt to set this variable to a value of less than one shall result in a badValue error. Those who are familiar with the SNMP management framework will recognize that thresholds are not in keeping with the SNMP philosophy. However, this variable is supported by underlying SMT implementations already and maintaining this threshold should not pose an undue additional burden on SNMP agent implementors." REFERENCE "ANSI { fddiMAC 95 }" ::= { snmpFddiMACEntry 23 } snmpFddiMACFrameErrorRatio OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is the actual ratio, ((delta snmpFddiMACLostCt + delta snmpFddiMACErrorCt) / (delta snmpFddiMACFrameCt + delta snmpFddiMACLostCt)) x 2**16." REFERENCE "ANSI { fddiMAC 96 }" ::= { snmpFddiMACEntry 24 } snmpFddiMACRMTState OBJECT-TYPE SYNTAX INTEGER { rm0(1), -- Isolated rm1(2), -- Non_Op rm2(3), -- Ring_Op rm3(4), -- Detect rm4(5), -- Non_Op_Dup rm5(6), -- Ring_Op_Dup rm6(7), -- Directed rm7(8) -- Trace } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current state of the Ring Management state machine (refer to ANSI Section 10)." REFERENCE "ANSI { fddiMAC 111 }" ::= { snmpFddiMACEntry 25 } snmpFddiMACDaFlag OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The RMT flag Duplicate Address Flag, DA_Flag (refer to ANSI 10.3.1.2)." REFERENCE "ANSI { fddiMAC 112 }" ::= { snmpFddiMACEntry 26 } snmpFddiMACUnaDaFlag OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag set when the upstream neighbor reports a duplicate address condition. Reset when the condition clears." REFERENCE "ANSI { fddiMAC 113 }" ::= { snmpFddiMACEntry 27 } snmpFddiMACFrameCondition OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the MAC Condition is active when set. Cleared when the condition clears and on power up." REFERENCE "ANSI { fddiMAC 114 }" ::= { snmpFddiMACEntry 28 } snmpFddiMACChipSet OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the hardware chip(s) which is (are) principally responsible for the implementation of the MAC function. A few OBJECT IDENTIFIERS are identified elsewhere in this memo. For those The assignment of additional OBJECT IDENTIFIERs to various types of hardware chip sets is managed by the IANA. For example, vendors whose chip sets are not defined in this memo may request a number from the Internet Assigned Numbers Authority (IANA) which indicates the assignment of a enterprise specific subtree which, among other things, may be used to allocate OBJECT IDENTIFIER assignments for that enterprise's chip sets. Similarly, in the absence of an appropriately assigned OBJECT IDENTIFIER in this memo or in an enterprise specific subtree of a chip vendor, a board or system vendor can request a number for a subtree from the IANA and make an appropriate assignment. It is desired that, whenever possible, the same OBJECT IDENTIFIER be used for all chips of a given type. Consequently, the assignment made in this memo for a chip, if any, should be used in preference to any other assignment and the assignment made by the chip manufacturer, if any, should be used in preference to assignments made by users of those chips. If the hardware chip set is unknown, the object identifier unknownChipSet OBJECT IDENTIFIER ::= { 0 0 } is returned. Note that unknownChipSet is a syntactically valid object identifier, and any conformant implementation of ASN.1 and the BER must be able to generate and recognize this value." ::= { snmpFddiMACEntry 29 } snmpFddiMACAction OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following enableLLCService(2), disableLLCService(3), connectMAC(4), disconnectMAC(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows: Other: Results in a badValue error. enableLLCService: enables MAC service to higher layers. disableLLCService: disables MAC service to higher layers. connectMAC: connect this MAC in station. disconnectMAC: disconnect this MAC in station. Attempts to set this object to all other values results in a badValue error." REFERENCE "ANSI { fddiMAC 130 }" ::= { snmpFddiMACEntry 30 } -- the PATH group -- the PATH group is empty for now and shall remain so until -- the ANSI community sorts out their PATH group -- the PORT group -- Implementation of the PORT group is mandatory for all -- systems which implement manageable FDDI subsystems. snmpFddiPORTNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of PORT implementations (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { snmpFddiPORT 1 } -- the PORT table snmpFddiPORTTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpFddiPORTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PORT entries. The number of entries is given by the value of snmpFddiPORTNumber." ::= { snmpFddiPORT 2 } snmpFddiPORTEntry OBJECT-TYPE SYNTAX SnmpFddiPORTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A PORT entry containing information common to a given PORT." INDEX { snmpFddiPORTSMTIndex, snmpFddiPORTIndex } ::= { snmpFddiPORTTable 1 } SnmpFddiPORTEntry ::= SEQUENCE { snmpFddiPORTSMTIndex INTEGER, snmpFddiPORTIndex INTEGER, snmpFddiPORTPCType INTEGER, snmpFddiPORTPCNeighbor INTEGER, snmpFddiPORTConnectionPolicies INTEGER, snmpFddiPORTRemoteMACIndicated INTEGER, snmpFddiPORTCEState INTEGER, snmpFddiPORTPathsRequested INTEGER, snmpFddiPORTMACPlacement FddiResourceId, snmpFddiPORTAvailablePaths INTEGER, snmpFddiPORTMACLoopTime FddiTime, snmpFddiPORTTBMax FddiTime, snmpFddiPORTBSFlag INTEGER, snmpFddiPORTLCTFailCts Counter, snmpFddiPORTLerEstimate INTEGER, snmpFddiPORTLemRejectCts Counter, snmpFddiPORTLemCts Counter, snmpFddiPORTLerCutoff INTEGER, snmpFddiPORTLerAlarm INTEGER, snmpFddiPORTConnectState INTEGER, snmpFddiPORTPCMState INTEGER, snmpFddiPORTPCWithhold INTEGER, snmpFddiPORTLerCondition INTEGER, snmpFddiPORTChipSet OBJECT IDENTIFIER, snmpFddiPORTAction INTEGER } snmpFddiPORTSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of the SMT index associated with this PORT." ::= { snmpFddiPORTEntry 1 } snmpFddiPORTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each PORT within a given SMT. Its value ranges between 1 and the sum of the values of snmpFddiSMTNonMasterCt { snmpFddiSMTEntry 6 } and snmpFddiSMTMasterCt { snmpFddiSMTEntry 7 } on the given SMT. The value for each PORT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { snmpFddiPORTEntry 2 } snmpFddiPORTPCType OBJECT-TYPE SYNTAX INTEGER { a(1), b(2), s(3), m(4) } ACCESS read-only STATUS mandatory DESCRIPTION "PC_Type (refer to ANSI SMT 9.2.2 and ANSI SMT 9.6.3.2)." REFERENCE "ANSI { fddiPORT 12 }" ::= { snmpFddiPORTEntry 3 } snmpFddiPORTPCNeighbor OBJECT-TYPE SYNTAX INTEGER { a(1), b(2), s(3), m(4), unknown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The type (PC_Neighbor) of the remote PORT that is determined in PC_Signaling in R_Val (1,2) (refer to ANSI SMT 9.6.3.2)." REFERENCE "ANSI { fddiPORT 13 }" ::= { snmpFddiPORTEntry 4 } snmpFddiPORTConnectionPolicies OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the node's PORT policies. Pc-MAC-LCT, Pc-MAC-Loop, and Pc-MAC-Placement indicate how the respective PC Signaling Capability flags should be set (refer to ANSI SMT 9.4.3.2). The value is a sum. This value initially takes the value zero, then for each PORT policy, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power Pc-MAC-LCT 0 Pc-MAC-Loop 1 Pc-MAC-Placement 2 " REFERENCE "ANSI { fddiPORT 14 }" ::= { snmpFddiPORTEntry 5 } snmpFddiPORTRemoteMACIndicated OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The indication, in PC-Signaling that the remote partner intends to place a MAC in the output token PATH of this PORT. Signaled as R_Val (9) (refer to ANSI SMT 9.6.3.2)." REFERENCE "ANSI { fddiPORT 15 }" ::= { snmpFddiPORTEntry 6 } snmpFddiPORTCEState OBJECT-TYPE SYNTAX INTEGER { ce0(1), -- Isolated ce1(2), -- Insert_P ce2(3), -- Insert_S ce3(4), -- Insert_X ce4(5) -- Local } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current state of PORT's Configuration Element (CE) (refer to ANSI 9.7.5). Note that this value represents the Current Path information for this PORT." REFERENCE "ANSI { fddiPORT 16 }" ::= { snmpFddiPORTEntry 7 } snmpFddiPORTPathsRequested OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "A value that indicates the desired association(s) of the port with a station PATH. The 'Primary' Path is the default. The value of 'Secondary' is only meaningful for S (slave) or M (master) PORT PC-Types. This value effects the setting of the CF_Insert_S, and CF_Insert_L flags (refer to ANSI Section 9.4.3). If the 'Primary' PATH is present, then the Primary PATH (the default PATH) is selected. If the 'Secondary' PATH is present and the 'Primary' PATH is not present, then the CF_Insert_S flag is set. If the 'Local' PATH is sent and neither the 'Primary' or 'Secondary' PATHs are sent, then the CF_Insert_L flag is set. The value is a sum. This value initially takes the value zero, then for each type of PATH desired, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 Isolated 3 " REFERENCE "ANSI { fddiPORT 17 }" ::= { snmpFddiPORTEntry 8 } snmpFddiPORTMACPlacement OBJECT-TYPE SYNTAX FddiResourceId -- INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the upstream MAC, if any, that is associated with the PORT. The value shall be zero if there is no MAC associated with the PORT. Otherwise, the value shall be equal to the value of snmpFddiMACIndex associated with the MAC." REFERENCE "ANSI { fddiPORT 18 }" ::= { snmpFddiPORTEntry 9 } snmpFddiPORTAvailablePaths OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A value that indicates the PATH types available for M and S PORTs. The value is a sum. This value initially takes the value zero, then for each type of PATH that this port has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 " REFERENCE "ANSI { fddiPORT 19 }" ::= { snmpFddiPORTEntry 10 } snmpFddiPORTMACLoopTime OBJECT-TYPE SYNTAX FddiTime ACCESS read-write STATUS mandatory DESCRIPTION "Time for the optional MAC Local Loop, T_Next(9), which is greater-than or equal-to 200 milliseconds (refer to ANSI SMT 9.4.4.2.3)." REFERENCE "ANSI { fddiPORT 21 }" ::= { snmpFddiPORTEntry 11 } snmpFddiPORTTBMax OBJECT-TYPE SYNTAX FddiTime ACCESS read-write STATUS mandatory DESCRIPTION "TB_Max (refer to ANSI SMT 9.4.4.2.1)." REFERENCE "ANSI { fddiPORT 32 }" ::= { snmpFddiPORTEntry 12 } snmpFddiPORTBSFlag OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Break State, BS_Flag (refer to ANSI SMT 9.4.3.4)." REFERENCE "ANSI { fddiPORT 33 }" ::= { snmpFddiPORTEntry 13 } snmpFddiPORTLCTFailCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of the consecutive times the link confidence test (LCT) has failed during connection management (refer to ANSI 9.4.1)." REFERENCE "ANSI { fddiPORT 42 }" ::= { snmpFddiPORTEntry 14 } snmpFddiPORTLerEstimate OBJECT-TYPE SYNTAX INTEGER (4..15) ACCESS read-only STATUS mandatory DESCRIPTION "A long term average link error rate. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent of the estimate." REFERENCE "ANSI { fddiPORT 51 }" ::= { snmpFddiPORTEntry 15 } snmpFddiPORTLemRejectCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A link error monitoring count of the times that a link has been rejected." REFERENCE "ANSI { fddiPORT 52 }" ::= { snmpFddiPORTEntry 16 } snmpFddiPORTLemCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The aggregate link error monitor error count, set to zero only on station power_up." REFERENCE "ANSI { fddiPORT 53 }" ::= { snmpFddiPORTEntry 17 } snmpFddiPORTLerCutoff OBJECT-TYPE SYNTAX INTEGER (4..15) ACCESS read-write STATUS mandatory DESCRIPTION "The link error rate estimate at which a link connection will be broken. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent." REFERENCE "ANSI { fddiPORT 58 }" ::= { snmpFddiPORTEntry 18 } snmpFddiPORTLerAlarm OBJECT-TYPE SYNTAX INTEGER (4..15) ACCESS read-write STATUS mandatory DESCRIPTION "The link error rate estimate at which a link connection will generate an alarm. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent of the estimate." REFERENCE "ANSI { fddiPORT 59 }" ::= { snmpFddiPORTEntry 19 } snmpFddiPORTConnectState OBJECT-TYPE SYNTAX INTEGER { disabled(1), connecting(2), standby(3), active(4) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the connect state of this PORT. Basically, this gives a higher level view of the state of the connection by grouping PCM states and the PC-Withhold flag state. The supported values and their corresponding PCM states and PC-Withhold condition, when relevant, are: disabled: (PC0:Off, PC9:Maint) connecting: (PC1(Break) || PC3 (Connect) || PC4 (Next) || PC5 (Signal) || PC6 (Join) || PC7 (Verify)) && (PC_Withhold = None) standby: (NOT PC_Withhold == None) active: (PC2:Trace || PC8:Active) " REFERENCE "ANSI { fddiPORT 61 }" ::= { snmpFddiPORTEntry 20 } snmpFddiPORTPCMState OBJECT-TYPE SYNTAX INTEGER { pc0(1), -- Off pc1(2), -- Break pc2(3), -- Trace pc3(4), -- Connect pc4(5), -- Next pc5(6), -- Signal pc6(7), -- Join pc7(8), -- Verify pc8(9), -- Active pc9(10) -- Maint } ACCESS read-only STATUS mandatory DESCRIPTION "(refer to SMT 9.6.2)." REFERENCE "ANSI { fddiPORT 62 }" ::= { snmpFddiPORTEntry 21 } snmpFddiPORTPCWithhold OBJECT-TYPE SYNTAX INTEGER { none(1), m-m(2), other(3) } ACCESS read-only STATUS mandatory DESCRIPTION "PC_Withhold, (refer to ANSI SMT 9.4.1)." REFERENCE "ANSI { fddiPORT 63 }" ::= { snmpFddiPORTEntry 22 } snmpFddiPORTLerCondition OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable is set to true whenever LerEstimate is less than or equal to LerAlarm." REFERENCE "ANSI { fddiPORT 64 }" ::= { snmpFddiPORTEntry 23 } snmpFddiPORTChipSet OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the hardware chip(s) which is (are) principally responsible for the implementation of the PORT (PHY) function. A few OBJECT IDENTIFIERS are identified elsewhere in this memo. For those The assignment of additional OBJECT IDENTIFIERs to various types of hardware chip sets is managed by the IANA. For example, vendors whose chip sets are not defined in this memo may request a number from the Internet Assigned Numbers Authority (IANA) which indicates the assignment of a enterprise specific subtree which, among other things, may be used to allocate OBJECT IDENTIFIER assignments for that enterprise's chip sets. Similarly, in the absence of an appropriately assigned OBJECT IDENTIFIER in this memo or in an enterprise specific subtree of a chip vendor, a board or system vendor can request a number for a subtree from the IANA and make an appropriate assignment. It is desired that, whenever possible, the same OBJECT IDENTIFIER be used for all chips of a given type. Consequently, the assignment made in this memo for a chip, if any, should be used in preference to any other assignment and the assignment made by the chip manufacturer, if any, should be used in preference to assignments made by users of those chips. If the hardware chip set is unknown, the object identifier unknownChipSet OBJECT IDENTIFIER ::= { 0 0 } is returned. Note that unknownChipSet is a syntactically valid object identifier, and any conformant implementation of ASN.1 and the BER must be able to generate and recognize this value." ::= { snmpFddiPORTEntry 24 } snmpFddiPORTAction OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following maintPORT(2), enablePORT(3), disablePORT(4), startPORT(5), stopPORT(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows: Other: Results in a badValue error. maintPORT: Signal PC_Maint enablePORT: Signal PC_Enable disablePORT: Signal PC_Disable startPORT: Signal PC_Start stopPORT: Signal PC_Stop Signals cause an SM_CM_CONTROL.request service to be generated with a control_action of `Signal' and the `variable' parameter set with the appropriate value (i.e., PC_Maint, PC_Enable, PC_Disable, PC_Start, PC_Stop). Ref. ANSI SMT Section 9.3.2. Attempts to set this object to all other values results in a badValue error." REFERENCE "ANSI { fddiPORT 70 }" ::= { snmpFddiPORTEntry 25 } -- the ATTACHMENT group -- Implementation of the ATTACHMENT group is mandatory for -- all systems which implement manageable FDDI subsystems. snmpFddiATTACHMENTNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of attachments (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { snmpFddiATTACHMENT 1 } -- the ATTACHMENT table snmpFddiATTACHMENTTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpFddiATTACHMENTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of ATTACHMENT entries. The number of entries is given by the value of snmpFddiATTACHMENTNumber." ::= { snmpFddiATTACHMENT 2 } snmpFddiATTACHMENTEntry OBJECT-TYPE SYNTAX SnmpFddiATTACHMENTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An ATTACHMENT entry containing information common to a given set of ATTACHMENTs. The ATTACHMENT Resource represents a PORT or a pair of PORTs plus the optional associated optical bypass that are managed as a functional unit. Because of its relationship to the PORT Objects, there is a natural association of ATTACHMENT Resource Indices to the PORT Indices. The resource index for the ATTACHMENT is equal to the associated PORT index for 'single-attachment' and 'concentrator' type snmpFddiATTACHMENTClasses. For 'dual-attachment' Classes, the ATTACHMENT Index is the PORT Index of the A PORT of the A/B PORT Pair that represents the ATTACHMENT." INDEX { snmpFddiATTACHMENTSMTIndex, snmpFddiATTACHMENTIndex } ::= { snmpFddiATTACHMENTTable 1 } SnmpFddiATTACHMENTEntry ::= SEQUENCE { snmpFddiATTACHMENTSMTIndex INTEGER, snmpFddiATTACHMENTIndex INTEGER, snmpFddiATTACHMENTClass INTEGER, snmpFddiATTACHMENTOpticalBypassPresent INTEGER, snmpFddiATTACHMENTIMaxExpiration FddiTime, snmpFddiATTACHMENTInsertedStatus INTEGER, snmpFddiATTACHMENTInsertPolicy INTEGER } snmpFddiATTACHMENTSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of the SMT index associated with this ATTACHMENT." ::= { snmpFddiATTACHMENTEntry 1 } snmpFddiATTACHMENTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each ATTACHMENT on a given SMT. Its value ranges between 1 and the sum of the values of snmpFddiSMTNonMasterCt { snmpFddiSMTEntry 6 } and snmpFddiSMTMasterCt { snmpFddiSMTEntry 7 } on the given SMT. The value for each ATTACHMENT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { snmpFddiATTACHMENTEntry 2 } snmpFddiATTACHMENTClass OBJECT-TYPE SYNTAX INTEGER { single-attachment(1), dual-attachment(2), concentrator(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The Attachment class. This represents a PORT or a pair of PORTs plus the associated optional optical bypass that are managed as a functional unit. The PORT associations are the following: single-attachment - S PORTs dual-attachment - A/B PORT Pairs concentrator - M PORTs " REFERENCE "ANSI { fddiATTACHMENT 11 }" ::= { snmpFddiATTACHMENTEntry 3 } snmpFddiATTACHMENTOpticalBypassPresent OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this value is false for 'single- attachment' and { snmpFddiATTACHMENT 11 }. Correct operation of CMT for single-attachment and concentrator attachments requires that a bypass function must not loopback the network side of the MIC, but only the node side." REFERENCE "ANSI { fddiATTACHMENT 12 }" ::= { snmpFddiATTACHMENTEntry 4 } snmpFddiATTACHMENTIMaxExpiration OBJECT-TYPE SYNTAX FddiTime ACCESS read-only STATUS mandatory DESCRIPTION "I_Max (refer to ANSI SMT 9.4.4.2.1). It is recognized that some currently deployed systems do not implement an optical bypass. Systems which do not implement optical bypass should return a value of 0." REFERENCE "ANSI { fddiATTACHMENT 13 }" ::= { snmpFddiATTACHMENTEntry 5 } snmpFddiATTACHMENTInsertedStatus OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unimplemented(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the attachment is currently inserted in the node." REFERENCE "ANSI { fddiATTACHMENT 14 }" ::= { snmpFddiATTACHMENTEntry 6 } snmpFddiATTACHMENTInsertPolicy OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unimplemented(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the Insert Policy for this Attachment. Insert: True (1), Don't Insert: False (2), Unimplemented (3)" REFERENCE "ANSI { fddiATTACHMENT 15 }" ::= { snmpFddiATTACHMENTEntry 7 } -- the Chip Set group -- The following object identifiers are allocated for use -- with the snmpFddiMACChipSet and snmpFddiPORTChipSet -- variables. snmpFddiPHYChipSets -- Chips primarily responsible -- for implementing the PHY -- function. OBJECT IDENTIFIER ::= { snmpFddiChipSets 1 } -- None defined at present -- Chipsets may someday be -- defined here snmpFddiMACChipSets -- Chips primarily responsible -- for implementing the -- MAC function. OBJECT IDENTIFIER ::= { snmpFddiChipSets 2 } -- None defined at present -- Chipsets may someday be -- defined here snmpFddiPHYMACChipSets -- Chips which implement both -- the PHY and MAC functions OBJECT IDENTIFIER ::= { snmpFddiChipSets 3 } -- None defined at present -- Chipsets may someday be -- defined here END