FLOW-METER-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Counter64, Integer32, mib-2 FROM SNMPv2-SMI TEXTUAL-CONVENTION, RowStatus, TimeStamp, TruthValue FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF ifIndex FROM IF-MIB TimeFilter FROM RMON2-MIB; flowMIB MODULE-IDENTITY LAST-UPDATED "9910250000Z" -- October 25, 1999 ORGANIZATION "IETF Realtime Traffic Flow Measurement Working Group" CONTACT-INFO "Nevil Brownlee, The University of Auckland Postal: Information Technology Sytems & Services The University of Auckland Private Bag 92-019 Auckland, New Zealand Phone: +64 9 373 7599 x8941 E-mail: n.brownlee@auckland.ac.nz" DESCRIPTION "MIB for the RTFM Traffic Flow Meter." REVISION "9910250000Z" DESCRIPTION "Initial Version, published as RFC 2720." REVISION "9908301250Z" DESCRIPTION "UTF8OwnerString Textual Convention added, and used to replace OwnerString. Conceptually the same as OwnerString, but facilitating internationalisation by using UTF-8 encoding for its characters rather than US-ASCII." REVISION "9908191010Z" DESCRIPTION "Changes to SIZE specification for two variables: - flowRuleInfoName SIZE specified as (0..127) - flowRuleIndex SIZE increased to (1..2147483647)" REVISION "9712230937Z" DESCRIPTION "Two further variables deprecated: - flowRuleInfoRulesReady (use flowRuleInfoStatus intead) - flowDataStatus (contains no useful information)" REVISION "9707071715Z" DESCRIPTION "Significant changes since RFC 2064 include: - flowDataPackageTable added - flowColumnActivityTable deprecated - flowManagerCounterWrap deprecated" REVISION "9603080208Z" DESCRIPTION "Initial version of this MIB (RFC 2064)" ::= { mib-2 40 } flowControl OBJECT IDENTIFIER ::= { flowMIB 1 } flowData OBJECT IDENTIFIER ::= { flowMIB 2 } flowRules OBJECT IDENTIFIER ::= { flowMIB 3 } flowMIBConformance OBJECT IDENTIFIER ::= { flowMIB 4 } -- Textual Conventions UTF8OwnerString ::= TEXTUAL-CONVENTION DISPLAY-HINT "127t" STATUS current DESCRIPTION "An administratively assigned name for the owner of a resource, conceptually the same as OwnerString in the RMON MIB [RMON-MIB]. To facilitate internationalisation, this name information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in the UTF-8 standard [UTF-8]." SYNTAX OCTET STRING (SIZE (0..127)) PeerType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the type of a PeerAddress (see below). The values used are from the 'Address Family Numbers' section of the Assigned Numbers RFC [ASG-NBR]. Peer types from other address families may also be used, provided only that they are identified by their assigned Address Family numbers." SYNTAX INTEGER { ipv4(1), ipv6(2), nsap(3), ipx(11), appletalk(12), decnet(13) } PeerAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Specifies the value of a peer address for various network protocols. Address format depends on the actual protocol, as indicated below: IPv4: ipv4(1) 4-octet IpAddress (defined in the SNMPv2 SMI [RFC2578]) IPv6: ipv6(2) 16-octet IpAddress (defined in the IPv6 Addressing RFC [V6-ADDR]) CLNS: nsap(3) NsapAddress (defined in the SNMPv2 SMI [RFC2578]) Novell: ipx(11) 4-octet Network number, 6-octet Host number (MAC address) AppleTalk: appletalk(12) 2-octet Network number (sixteen bits), 1-octet Host number (eight bits) DECnet: decnet(13) 1-octet Area number (in low-order six bits), 2-octet Host number (in low-order ten bits) " SYNTAX OCTET STRING (SIZE (3..20)) AdjacentType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the type of an adjacent address. May be a medium type or (if metering is taking place inside a tunnel) a PeerType (see above). The values used for IEEE 802 medium types are from the 'Network Management Parameters (ifType definitions)' section of the Assigned Numbers RFC [ASG-NBR]. Other medium types may also be used, provided only that they are identified by their assigned ifType numbers." SYNTAX INTEGER { ip(1), nsap(3), ethernet(7), -- ethernet-like [ENET-OBJ], -- includes ethernet-csmacd(6) tokenring(9), ipx(11), appletalk(12), decnet(13), fddi(15) } AdjacentAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Specifies the value of an adjacent address. May be a Medium Access Control (MAC) address or (if metering is taking place inside a tunnel) a PeerAddress (see above). MAC Address format depends on the actual medium, as follows: Ethernet: ethernet(7) 6-octet 802.3 MAC address in 'canonical' order Token Ring: tokenring(9) 6-octet 802.5 MAC address in 'canonical' order FDDI: fddi(15) FddiMACLongAddress, i.e. a 6-octet MAC address in 'canonical' order (defined in [FDDI-MIB]) " SYNTAX OCTET STRING (SIZE (3..20)) TransportType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the type of a TransportAddress (see below). Values will depend on the actual protocol; for IP they will be those given in the 'Protocol Numbers' section of the Assigned Numbers RFC [ASG-NBR], including icmp(1), tcp(6) and udp(17)." SYNTAX Integer32 (1..255) TransportAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Specifies the value of a transport address for various network protocols. Format as follows: IP: 2-octet UDP or TCP port number Other protocols: 2-octet port number " SYNTAX OCTET STRING (SIZE (2)) RuleAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Specifies the value of an address. Is a superset of MediumAddress, PeerAddress and TransportAddress." SYNTAX OCTET STRING (SIZE (2..20)) FlowAttributeNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Uniquely identifies an attribute within a flow data record." SYNTAX INTEGER { flowIndex(1), flowStatus(2), flowTimeMark(3), sourceInterface(4), sourceAdjacentType(5), sourceAdjacentAddress(6), sourceAdjacentMask(7), sourcePeerType(8), sourcePeerAddress(9), sourcePeerMask(10), sourceTransType(11), sourceTransAddress(12), sourceTransMask(13), destInterface(14), destAdjacentType(15), destAdjacentAddress(16), destAdjacentMask(17), destPeerType(18), destPeerAddress(19), destPeerMask(20), destTransType(21), destTransAddress(22), destTransMask(23), pduScale(24), octetScale(25), ruleSet(26), toOctets(27), -- Source-to-Dest toPDUs(28), fromOctets(29), -- Dest-to-Source fromPDUs(30), firstTime(31), -- Activity times lastActiveTime(32), sourceSubscriberID(33), -- Subscriber ID destSubscriberID(34), sessionID(35), sourceClass(36), -- Computed attributes destClass(37), flowClass(38), sourceKind(39), destKind(40), flowKind(41) } RuleAttributeNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Uniquely identifies an attribute which may be tested in a rule. These include attributes whose values come directly from (or are computed from) the flow's packets, and the five 'meter' variables used to hold an Attribute Number." SYNTAX INTEGER { null(0), sourceInterface(4), -- Source Address sourceAdjacentType(5), sourceAdjacentAddress(6), sourcePeerType(8), sourcePeerAddress(9), sourceTransType(11), sourceTransAddress(12), destInterface(14), -- Dest Address destAdjacentType(15), destAdjacentAddress(16), destPeerType(18), destPeerAddress(19), destTransType(21), destTransAddress(22), sourceSubscriberID(33), -- Subscriber ID destSubscriberID(34), sessionID(35), sourceClass(36), -- Computed attributes destClass(37), flowClass(38), sourceKind(39), destKind(40), flowKind(41), matchingStoD(50), -- Packet matching v1(51), -- Meter variables v2(52), v3(53), v4(54), v5(55) } ActionNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Uniquely identifies the action of a rule, i.e. the Pattern Matching Engine's opcode number. Details of the opcodes are given in the 'Traffic Flow Measurement: Architecture' document [RTFM-ARC]." SYNTAX INTEGER { ignore(1), noMatch(2), count(3), countPkt(4), return(5), gosub(6), gosubAct(7), assign(8), assignAct(9), goto(10), gotoAct(11), pushRuleTo(12), pushRuleToAct(13), pushPktTo(14), pushPktToAct(15), popTo(16), popToAct(17) } -- -- Control Group: RuleSet Info Table -- flowRuleSetInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowRuleSetInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An array of information about the RuleSets held in the meter. Any manager may configure a new RuleSet for the meter by creating a row in this table with status active(1), and setting values for all the objects in its rules. At this stage the new RuleSet is available but not 'running', i.e. it is not being used by the meter to produce entries in the flow table. To actually 'run' a RuleSet a manager must create a row in the flowManagerInfoTable, set it's flowManagerStatus to active(1), and set either its CurrentRuleSet or StandbyRuleSet to point to the RuleSet to be run. Once a RuleSet is running a manager may not change any of the objects within the RuleSet itself. Any attempt to do so should result in a notWritable(17) SNMP error-status for such objects. A manager may stop a RuleSet running by removing all references to it in the flowManagerInfoTable (i.e. by setting CurrentRuleSet and StandbyRuleSet values to 0). This provides a way to stop RuleSets left running if a manager fails. For example, when a manager is started, it could search the meter's flowManager table and stop all RuleSets having a specified value of flowRuleInfoOwner. To prevent a manager from interfering with variables belonging to another manager, the meter should use MIB views [RFC2575] so as to limit each manager's access to the meter's variables, effectively dividing the single meter into several virtual meters, one for each independent manager." ::= { flowControl 1 } flowRuleSetInfoEntry OBJECT-TYPE SYNTAX FlowRuleSetInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular RuleSet." INDEX { flowRuleInfoIndex } ::= { flowRuleSetInfoTable 1 } FlowRuleSetInfoEntry ::= SEQUENCE { flowRuleInfoIndex Integer32, flowRuleInfoSize Integer32, flowRuleInfoOwner UTF8OwnerString, flowRuleInfoTimeStamp TimeStamp, flowRuleInfoStatus RowStatus, flowRuleInfoName OCTET STRING, flowRuleInfoRulesReady TruthValue, flowRuleInfoFlowRecords Integer32 } flowRuleInfoIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index which selects an entry in the flowRuleSetInfoTable. Each such entry contains control information for a particular RuleSet which the meter may run." ::= { flowRuleSetInfoEntry 1 } flowRuleInfoSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Number of rules in this RuleSet. Setting this variable will cause the meter to allocate space for these rules." ::= { flowRuleSetInfoEntry 2 } flowRuleInfoOwner OBJECT-TYPE SYNTAX UTF8OwnerString MAX-ACCESS read-create STATUS current DESCRIPTION "Identifies the manager which 'owns' this RuleSet. A manager must set this variable when creating a row in this table." ::= { flowRuleSetInfoEntry 3 } flowRuleInfoTimeStamp OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "Time this row's associated RuleSet was last changed." ::= { flowRuleSetInfoEntry 4 } flowRuleInfoStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this flowRuleSetInfoEntry. If this value is not active(1) the meter must not attempt to use the row's associated RuleSet. Once its value has been set to active(1) a manager may not change any of the other variables in the row, nor the contents of the associated RuleSet. Any attempt to do so should result in a notWritable(17) SNMP error-status for such variables or objects. To download a RuleSet, a manger could: - Locate an open slot in the RuleSetInfoTable. - Create a RuleSetInfoEntry by setting the status for this open slot to createAndWait(5). - Set flowRuleInfoSize and flowRuleInfoName as required. - Download the rules into the row's rule table. - Set flowRuleInfoStatus to active(1). The RuleSet would then be ready to run. The manager is not allowed to change the value of flowRuleInfoStatus from active(1) if the associated RuleSet is being referenced by any of the entries in the flowManagerInfoTable. Setting RuleInfoStatus to destroy(6) destroys the associated RuleSet together with any flow data collected by it." ::= { flowRuleSetInfoEntry 5 } flowRuleInfoName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..127)) MAX-ACCESS read-create STATUS current DESCRIPTION "An alphanumeric identifier used by managers and readers to identify a RuleSet. For example, a manager wishing to run a RuleSet named WWW-FLOWS could search the flowRuleSetInfoTable to see whether the WWW-FLOWS RuleSet is already available on the meter. Note that references to RuleSets in the flowManagerInfoTable use indexes for their flowRuleSetInfoTable entries. These may be different each time the RuleSet is loaded into a meter." ::= { flowRuleSetInfoEntry 6 } flowRuleInfoRulesReady OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Indicates whether the rules for this row's associated RuleSet are ready for use. The meter will refuse to 'run' the RuleSet unless this variable has been set to true(1). While RulesReady is false(2), the manager may modify the RuleSet, for example by downloading rules into it." ::= { flowRuleSetInfoEntry 7 } flowRuleInfoFlowRecords OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in the flow table for this RuleSet. These may be current (waiting for collection by one or more meter readers) or idle (waiting for the meter to recover their memory)." ::= { flowRuleSetInfoEntry 8 } -- -- Control Group: Interface Info Table -- flowInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An array of information specific to each meter interface." ::= { flowControl 2 } flowInterfaceEntry OBJECT-TYPE SYNTAX FlowInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular interface." INDEX { ifIndex } ::= { flowInterfaceTable 1 } FlowInterfaceEntry ::= SEQUENCE { flowInterfaceSampleRate Integer32, flowInterfaceLostPackets Counter32 } flowInterfaceSampleRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The parameter N for statistical counting on this interface. Set to N to count 1/Nth of the packets appearing at this interface. A sampling rate of 1 counts all packets. A sampling rate of 0 results in the interface being ignored by the meter. A meter should choose its own algorithm to introduce variance into the sampling so that exactly every Nth packet is counted. The IPPM Working Group's RFC 'Framework for IP Performance Metrics' [IPPM-FRM] explains why this should be done, and sets out an algorithm for doing it." DEFVAL { 1 } ::= { flowInterfaceEntry 1 } flowInterfaceLostPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets the meter has lost for this interface. Such losses may occur because the meter has been unable to keep up with the traffic volume." ::= { flowInterfaceEntry 2 } -- -- Control Group: Meter Reader Info Table -- -- Any meter reader wishing to collect data reliably for flows -- should first create a row in this table. It should write that -- row's flowReaderLastTime object each time it starts a collection -- pass through the flow table. -- If a meter reader (MR) does not create a row in this table, e.g. -- because its MIB view [RFC2575] did not allow MR create access to -- flowReaderStatus, collection can still proceed but the meter will -- not be aware of meter reader MR. This could lead the meter to -- recover flows before they have been collected by MR. flowReaderInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowReaderInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An array of information about meter readers which have registered their intent to collect flow data from this meter." ::= { flowControl 3 } flowReaderInfoEntry OBJECT-TYPE SYNTAX FlowReaderInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular meter reader." INDEX { flowReaderIndex } ::= { flowReaderInfoTable 1 } FlowReaderInfoEntry ::= SEQUENCE { flowReaderIndex Integer32, flowReaderTimeout Integer32, flowReaderOwner UTF8OwnerString, flowReaderLastTime TimeStamp, flowReaderPreviousTime TimeStamp, flowReaderStatus RowStatus, flowReaderRuleSet Integer32 } flowReaderIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index which selects an entry in the flowReaderInfoTable." ::= { flowReaderInfoEntry 1 } flowReaderTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the maximum time (in seconds) between flow data collections for this meter reader. If this time elapses without a collection, the meter should assume that this meter reader has stopped collecting, and delete this row from the table. A value of zero indicates that this row should not be timed out." ::= { flowReaderInfoEntry 2 } flowReaderOwner OBJECT-TYPE SYNTAX UTF8OwnerString MAX-ACCESS read-create STATUS current DESCRIPTION "Identifies the meter reader which created this row." ::= { flowReaderInfoEntry 3 } flowReaderLastTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-create STATUS current DESCRIPTION "Time this meter reader began its most recent data collection. This variable should be written by a meter reader as its first step in reading flow data. The meter will set this LastTime value to its current Uptime, and set its PreviousTime value (below) to the old LastTime. This allows the meter to recover flows which have been inactive since PreviousTime, for these have been collected at least once. If the meter reader fails to write flowLastReadTime, collection may still proceed but the meter may not be able to recover inactive flows until the flowReaderTimeout has been reached for this entry." ::= { flowReaderInfoEntry 4 } flowReaderPreviousTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "Time this meter reader began the collection before last." ::= { flowReaderInfoEntry 5 } flowReaderStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this FlowReaderInfoEntry. A value of active(1) implies that the associated reader should be collecting data from the meter. Once this variable has been set to active(1) a manager may only change this row's flowReaderLastTime and flowReaderTimeout variables." ::= { flowReaderInfoEntry 6 } flowReaderRuleSet OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "An index to the array of RuleSets. Specifies a set of rules of interest to this meter reader. The reader will attempt to collect any data generated by the meter for this RuleSet, and the meter will not recover the memory of any of the RuleSet's flows until this collection has taken place. Note that a reader may have entries in this table for several RuleSets." ::= { flowReaderInfoEntry 7 } -- -- Control Group: Manager Info Table -- -- Any manager wishing to run a RuleSet must create a row in this -- table. Once it has a table row, the manager may set the control -- variables in its row so as to cause the meter to run any valid -- RuleSet held by the meter. -- A single manager may run several RuleSets; it must create a row -- in this table for each of them. In short, each row of this table -- describes (and controls) a 'task' which the meter is executing. flowManagerInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowManagerInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An array of information about managers which have registered their intent to run RuleSets on this meter." ::= { flowControl 4 } flowManagerInfoEntry OBJECT-TYPE SYNTAX FlowManagerInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular meter 'task.' By creating an entry in this table and activating it, a manager requests that the meter 'run' the indicated RuleSet. The entry also specifies a HighWaterMark and a StandbyRuleSet. If the meter's flow table usage exceeds this task's HighWaterMark the meter will stop running the task's CurrentRuleSet and switch to its StandbyRuleSet. If the value of the task's StandbyRuleSet is 0 when its HighWaterMark is exceeded, the meter simply stops running the task's CurrentRuleSet. By careful selection of HighWaterMarks for the various tasks a manager can ensure that the most critical RuleSets are the last to stop running as the number of flows increases. When a manager has determined that the demand for flow table space has abated, it may cause the task to switch back to its CurrentRuleSet by setting its flowManagerRunningStandby variable to false(2)." INDEX { flowManagerIndex } ::= { flowManagerInfoTable 1 } FlowManagerInfoEntry ::= SEQUENCE { flowManagerIndex Integer32, flowManagerCurrentRuleSet Integer32, flowManagerStandbyRuleSet Integer32, flowManagerHighWaterMark Integer32, flowManagerCounterWrap INTEGER, flowManagerOwner UTF8OwnerString, flowManagerTimeStamp TimeStamp, flowManagerStatus RowStatus, flowManagerRunningStandby TruthValue } flowManagerIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index which selects an entry in the flowManagerInfoTable." ::= { flowManagerInfoEntry 1 } flowManagerCurrentRuleSet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Index to the array of RuleSets. Specifies which set of rules is the 'current' one for this task. The meter will be 'running' the current RuleSet if this row's flowManagerRunningStandby value is false(2). When the manager sets this variable the meter will stop using the task's old current RuleSet and start using the new one. Specifying RuleSet 0 (the empty set) stops flow measurement for this task." ::= { flowManagerInfoEntry 2 } flowManagerStandbyRuleSet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Index to the array of RuleSets. After reaching HighWaterMark (see below) the manager will switch to using the task's StandbyRuleSet in place of its CurrentRuleSet. For this to be effective the designated StandbyRuleSet should have a coarser reporting granularity then the CurrentRuleSet. The manager may also need to decrease the meter reading interval so that the meter can recover flows measured by this task's CurrentRuleSet." DEFVAL { 0 } -- No standby ::= { flowManagerInfoEntry 3 } flowManagerHighWaterMark OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-create STATUS current DESCRIPTION "A value expressed as a percentage, interpreted by the meter as an indication of how full the flow table should be before it should switch to the standby RuleSet (if one has been specified) for this task. Values of 0% or 100% disable the checking represented by this variable." ::= { flowManagerInfoEntry 4 } flowManagerCounterWrap OBJECT-TYPE SYNTAX INTEGER { wrap(1), scale(2) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Specifies whether PDU and octet counters should wrap when they reach the top of their range (normal behaviour for Counter64 objects), or whether their scale factors should be used instead. The combination of counter and scale factor allows counts to be returned as non-negative binary floating point numbers, with 64-bit mantissas and 8-bit exponents." DEFVAL { wrap } ::= { flowManagerInfoEntry 5 } flowManagerOwner OBJECT-TYPE SYNTAX UTF8OwnerString MAX-ACCESS read-create STATUS current DESCRIPTION "Identifies the manager which created this row." ::= { flowManagerInfoEntry 6 } flowManagerTimeStamp OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "Time this row was last changed by its manager." ::= { flowManagerInfoEntry 7 } flowManagerStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this row in the flowManagerInfoTable. A value of active(1) implies that this task may be activated, by setting its CurrentRuleSet and StandbyRuleSet variables. Its HighWaterMark and RunningStandby variables may also be changed." ::= { flowManagerInfoEntry 8 } flowManagerRunningStandby OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Set to true(1) by the meter to indicate that it has switched to runnning this task's StandbyRuleSet in place of its CurrentRuleSet. To switch back to the CurrentRuleSet, the manager may simply set this variable to false(2)." DEFVAL { false } ::= { flowManagerInfoEntry 9 } -- -- Control Group: General Meter Control Variables -- flowFloodMark OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "A value expressed as a percentage, interpreted by the meter as an indication of how full the flow table should be before it should take some action to avoid running out of resources to handle new flows, as discussed in section 4.6 (Handling Increasing Traffic Levels) of the RTFM Architecture RFC [RTFM-ARC]. Values of 0% or 100% disable the checking represented by this variable." DEFVAL { 95 } -- Enabled by default. ::= { flowControl 5 } flowInactivityTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds since the last packet seen, after which a flow becomes 'idle.' Note that although a flow may be idle, it will not be discarded (and its memory recovered) until after its data has been collected by all the meter readers registered for its RuleSet." DEFVAL { 600 } -- 10 minutes ::= { flowControl 6 } flowActiveFlows OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of flows which are currently in use." ::= { flowControl 7 } flowMaxFlows OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of flows allowed in the meter's flow table. At present this is determined when the meter is first started up." ::= { flowControl 8 } flowFloodMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates that the meter has passed its FloodMark and is not running in its normal mode. When the manager notices this it should take action to remedy the problem which caused the flooding. It should then monitor flowActiveFlows so as to determine when the flood has receded. At that point the manager may set flowFloodMode to false(2) to resume normal operation." ::= { flowControl 9 } -- -- The Flow Table -- -- This is a table kept by a meter, with one flow data entry for every -- flow being measured. Each flow data entry stores the attribute -- values for a traffic flow. Details of flows and their attributes -- are given in the 'Traffic Flow Measurement: Architecture' -- document [RTFM-ARC]. -- From time to time a meter reader may sweep the flow table so as -- to read counts. This is most effectively achieved by using the -- TimeMark variable together with successive GetBulk requests to -- retrieve the values of the desired flow attribute variables. -- This scheme allows multiple meter readers to independently use the -- same meter; the meter readers do not have to be synchronised and -- they may use different collection intervals. -- If identical sets of counts are required from a meter, a manager -- could achieve this using two identical copies of a RuleSet in that -- meter and switching back and forth between them. This is discussed -- further in the RTFM Architecture document [RTFM-ARC]. flowDataTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of all flows being measured." ::= { flowData 1 } flowDataEntry OBJECT-TYPE SYNTAX FlowDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The flow data record for a particular flow." INDEX { flowDataRuleSet, flowDataTimeMark, flowDataIndex } ::= { flowDataTable 1 } FlowDataEntry ::= SEQUENCE { flowDataIndex Integer32, flowDataTimeMark TimeFilter, flowDataStatus INTEGER, flowDataSourceInterface Integer32, flowDataSourceAdjacentType AdjacentType, flowDataSourceAdjacentAddress AdjacentAddress, flowDataSourceAdjacentMask AdjacentAddress, flowDataSourcePeerType PeerType, flowDataSourcePeerAddress PeerAddress, flowDataSourcePeerMask PeerAddress, flowDataSourceTransType TransportType, flowDataSourceTransAddress TransportAddress, flowDataSourceTransMask TransportAddress, flowDataDestInterface Integer32, flowDataDestAdjacentType AdjacentType, flowDataDestAdjacentAddress AdjacentAddress, flowDataDestAdjacentMask AdjacentAddress, flowDataDestPeerType PeerType, flowDataDestPeerAddress PeerAddress, flowDataDestPeerMask PeerAddress, flowDataDestTransType TransportType, flowDataDestTransAddress TransportAddress, flowDataDestTransMask TransportAddress, flowDataPDUScale Integer32, flowDataOctetScale Integer32, flowDataRuleSet Integer32, flowDataToOctets Counter64, -- Source->Dest flowDataToPDUs Counter64, flowDataFromOctets Counter64, -- Dest->Source flowDataFromPDUs Counter64, flowDataFirstTime TimeStamp, -- Activity times flowDataLastActiveTime TimeStamp, flowDataSourceSubscriberID OCTET STRING, flowDataDestSubscriberID OCTET STRING, flowDataSessionID OCTET STRING, flowDataSourceClass Integer32, flowDataDestClass Integer32, flowDataClass Integer32, flowDataSourceKind Integer32, flowDataDestKind Integer32, flowDataKind Integer32 } flowDataIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Value of this flow data record's index within the meter's flow table." ::= { flowDataEntry 1 } flowDataTimeMark OBJECT-TYPE SYNTAX TimeFilter MAX-ACCESS not-accessible STATUS current DESCRIPTION "A TimeFilter for this entry. Allows GetNext and GetBulk to find flow table rows which have changed since a specified value of the meter's Uptime." ::= { flowDataEntry 2 } flowDataStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), current(2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Status of this flow data record." ::= { flowDataEntry 3 } flowDataSourceInterface OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the interface associated with the source address for this flow. It's value is one of those contained in the ifIndex field of the meter's interfaces table." ::= { flowDataEntry 4 } flowDataSourceAdjacentType OBJECT-TYPE SYNTAX AdjacentType MAX-ACCESS read-only STATUS current DESCRIPTION "Adjacent address type of the source for this flow. If metering is being performed at the network level, AdjacentType will indicate the medium for the interface on which the flow was observed and AdjacentAddress will be the MAC address for that interface. This is the usual case. If traffic is being metered inside a tunnel, AdjacentType will be the peer type of the host at the end of the tunnel and AdjacentAddress will be the peer address for that host." ::= { flowDataEntry 5 } flowDataSourceAdjacentAddress OBJECT-TYPE SYNTAX AdjacentAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Address of the adjacent device on the path for the source for this flow." ::= { flowDataEntry 6 } flowDataSourceAdjacentMask OBJECT-TYPE SYNTAX AdjacentAddress MAX-ACCESS read-only STATUS current DESCRIPTION "1-bits in this mask indicate which bits must match when comparing the adjacent source address for this flow." ::= { flowDataEntry 7 } flowDataSourcePeerType OBJECT-TYPE SYNTAX PeerType MAX-ACCESS read-only STATUS current DESCRIPTION "Peer address type of the source for this flow." ::= { flowDataEntry 8 } flowDataSourcePeerAddress OBJECT-TYPE SYNTAX PeerAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Address of the peer device for the source of this flow." ::= { flowDataEntry 9 } flowDataSourcePeerMask OBJECT-TYPE SYNTAX PeerAddress MAX-ACCESS read-only STATUS current DESCRIPTION "1-bits in this mask indicate which bits must match when comparing the source peer address for this flow." ::= { flowDataEntry 10 } flowDataSourceTransType OBJECT-TYPE SYNTAX TransportType MAX-ACCESS read-only STATUS current DESCRIPTION "Transport address type of the source for this flow. The value of this attribute will depend on the peer address type." ::= { flowDataEntry 11 } flowDataSourceTransAddress OBJECT-TYPE SYNTAX TransportAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Transport address for the source of this flow." ::= { flowDataEntry 12 } flowDataSourceTransMask OBJECT-TYPE SYNTAX TransportAddress MAX-ACCESS read-only STATUS current DESCRIPTION "1-bits in this mask indicate which bits must match when comparing the transport source address for this flow." ::= { flowDataEntry 13 } flowDataDestInterface OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the interface associated with the dest address for this flow. This value is one of the values contained in the ifIndex field of the interfaces table." ::= { flowDataEntry 14 } flowDataDestAdjacentType OBJECT-TYPE SYNTAX AdjacentType MAX-ACCESS read-only STATUS current DESCRIPTION "Adjacent address type of the destination for this flow." ::= { flowDataEntry 15 } flowDataDestAdjacentAddress OBJECT-TYPE SYNTAX AdjacentAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Address of the adjacent device on the path for the destination for this flow." ::= { flowDataEntry 16 } flowDataDestAdjacentMask OBJECT-TYPE SYNTAX AdjacentAddress MAX-ACCESS read-only STATUS current DESCRIPTION "1-bits in this mask indicate which bits must match when comparing the adjacent destination address for this flow." ::= { flowDataEntry 17 } flowDataDestPeerType OBJECT-TYPE SYNTAX PeerType MAX-ACCESS read-only STATUS current DESCRIPTION "Peer address type of the destination for this flow." ::= { flowDataEntry 18 } flowDataDestPeerAddress OBJECT-TYPE SYNTAX PeerAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Address of the peer device for the destination of this flow." ::= { flowDataEntry 19 } flowDataDestPeerMask OBJECT-TYPE SYNTAX PeerAddress MAX-ACCESS read-only STATUS current DESCRIPTION "1-bits in this mask indicate which bits must match when comparing the destination peer type for this flow." ::= { flowDataEntry 20 } flowDataDestTransType OBJECT-TYPE SYNTAX TransportType MAX-ACCESS read-only STATUS current DESCRIPTION "Transport address type of the destination for this flow. The value of this attribute will depend on the peer address type." ::= { flowDataEntry 21 } flowDataDestTransAddress OBJECT-TYPE SYNTAX TransportAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Transport address for the destination of this flow." ::= { flowDataEntry 22 } flowDataDestTransMask OBJECT-TYPE SYNTAX TransportAddress MAX-ACCESS read-only STATUS current DESCRIPTION "1-bits in this mask indicate which bits must match when comparing the transport destination address for this flow." ::= { flowDataEntry 23 } flowDataPDUScale OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The scale factor applied to this particular flow. Indicates the number of bits the PDU counter values should be moved left to obtain the actual values." ::= { flowDataEntry 24 } flowDataOctetScale OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The scale factor applied to this particular flow. Indicates the number of bits the octet counter values should be moved left to obtain the actual values." ::= { flowDataEntry 25 } flowDataRuleSet OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RuleSet number of the RuleSet which created this flow. Allows a manager to use GetNext or GetBulk requests to find flows belonging to a particular RuleSet." ::= { flowDataEntry 26 } flowDataToOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of octets flowing from source to destination for this flow." ::= { flowDataEntry 27 } flowDataToPDUs OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of packets flowing from source to destination for this flow." ::= { flowDataEntry 28 } flowDataFromOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of octets flowing from destination to source for this flow." ::= { flowDataEntry 29 } flowDataFromPDUs OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of packets flowing from destination to source for this flow." ::= { flowDataEntry 30 } flowDataFirstTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The time at which this flow was first entered in the table" ::= { flowDataEntry 31 } flowDataLastActiveTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The last time this flow had activity, i.e. the time of arrival of the most recent PDU belonging to this flow." ::= { flowDataEntry 32 } flowDataSourceSubscriberID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Subscriber ID associated with the source address for this flow. A Subscriber ID is an unspecified text string, used to ascribe traffic flows to individual users. At this time the means by which a Subscriber ID may be associated with a flow is unspecified." ::= { flowDataEntry 33 } flowDataDestSubscriberID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Subscriber ID associated with the destination address for this flow. A Subscriber ID is an unspecified text string, used to ascribe traffic flows to individual users. At this time the means by which a Subscriber ID may be associated with a flow is unspecified." ::= { flowDataEntry 34 } flowDataSessionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Session ID for this flow. Such an ID might be allocated by a network access server to distinguish a series of sessions between the same pair of addresses, which would otherwise appear to be parts of the same accounting flow." ::= { flowDataEntry 35 } flowDataSourceClass OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Source class for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table." ::= { flowDataEntry 36 } flowDataDestClass OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Destination class for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table." ::= { flowDataEntry 37 } flowDataClass OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Class for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table." ::= { flowDataEntry 38 } flowDataSourceKind OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Source kind for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table." ::= { flowDataEntry 39 } flowDataDestKind OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Destination kind for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table." ::= { flowDataEntry 40 } flowDataKind OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Class for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table." ::= { flowDataEntry 41 } -- -- The Activity Column Table -- flowColumnActivityTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowColumnActivityEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Index into the Flow Table. Allows a meter reader to retrieve a list containing the flow table indexes of flows which were last active at or after a given time, together with the values of a specified attribute for each such flow." ::= { flowData 2 } flowColumnActivityEntry OBJECT-TYPE SYNTAX FlowColumnActivityEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "The Column Activity Entry for a particular attribute, activity time and flow." INDEX { flowColumnActivityAttribute, flowColumnActivityTime, flowColumnActivityIndex } ::= { flowColumnActivityTable 1 } FlowColumnActivityEntry ::= SEQUENCE { flowColumnActivityAttribute FlowAttributeNumber, flowColumnActivityTime TimeFilter, flowColumnActivityIndex Integer32, flowColumnActivityData OCTET STRING } flowColumnActivityAttribute OBJECT-TYPE SYNTAX FlowAttributeNumber MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Specifies the attribute for which values are required from active flows." ::= { flowColumnActivityEntry 1 } flowColumnActivityTime OBJECT-TYPE SYNTAX TimeFilter MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This variable is a copy of flowDataLastActiveTime in the flow data record identified by the flowColumnActivityIndex value of this flowColumnActivityTable entry." ::= { flowColumnActivityEntry 2 } flowColumnActivityIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Index of a flow table entry which was active at or after a specified flowColumnActivityTime." ::= { flowColumnActivityEntry 3 } flowColumnActivityData OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3..1000)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Collection of attribute data for flows active after flowColumnActivityTime. Within the OCTET STRING is a sequence of { flow index, attribute value } pairs, one for each active flow. The end of the sequence is marked by a flow index value of 0, indicating that there are no more rows in this column. The format of objects inside flowColumnFlowData is as follows. All numbers are unsigned. Numbers and strings appear with their high-order bytes leading. Numbers are fixed size, as specified by their SYNTAX in the flow table (above), i.e. one octet for flowAddressType and small constants, and four octets for Counter and TimeStamp. Strings are variable-length, with the length given in a single leading octet. The following is an attempt at an ASN.1 definition of flowColumnActivityData: flowColumnActivityData ::= SEQUENCE flowRowItemEntry flowRowItemEntry ::= SEQUENCE { flowRowNumber Integer32 (1..65535), -- 0 indicates the end of this column flowDataValue flowDataType -- Choice depends on attribute } flowDataType ::= CHOICE { flowByteValue Integer32 (1..255), flowShortValue Integer32 (1..65535), flowLongValue Integer32, flowStringValue OCTET STRING -- Length (n) in first byte, -- n+1 bytes total length, trailing zeroes truncated }" ::= { flowColumnActivityEntry 4 } -- -- The Data Package Table -- flowDataPackageTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowDataPackageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into the Flow Table. Allows a meter reader to retrieve a sequence containing the values of a specified set of attributes for a flow which came from a specified RuleSet and which was last active at or after a given time." ::= { flowData 3 } flowDataPackageEntry OBJECT-TYPE SYNTAX FlowDataPackageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The data package containing selected variables from active rows in the flow table." INDEX { flowPackageSelector, flowPackageRuleSet, flowPackageTime, flowPackageIndex } ::= { flowDataPackageTable 1 } FlowDataPackageEntry ::= SEQUENCE { flowPackageSelector OCTET STRING, flowPackageRuleSet Integer32, flowPackageTime TimeFilter, flowPackageIndex Integer32, flowPackageData OCTET STRING } flowPackageSelector OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "Specifies the attributes for which values are required from an active flow. These are encoded as a sequence of octets each containing a FlowAttribute number, preceded by an octet giving the length of the sequence (not including the length octet). For a flowPackageSelector to be valid, it must contain at least one attribute." ::= { flowDataPackageEntry 1 } flowPackageRuleSet OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Specifies the index (in the flowRuleSetInfoTable) of the rule set which produced the required flow." ::= { flowDataPackageEntry 2 } flowPackageTime OBJECT-TYPE SYNTAX TimeFilter MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable is a copy of flowDataLastActiveTime in the flow data record identified by the flowPackageIndex value of this flowPackageTable entry." ::= { flowDataPackageEntry 3 } flowPackageIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of a flow table entry which was active at or after a specified flowPackageTime." ::= { flowDataPackageEntry 4 } flowPackageData OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "A collection of attribute values for a single flow, as specified by this row's indexes. The attribute values are contained within a BER-encoded sequence [ASN-1, ASN-BER], in the order they appear in their flowPackageSelector. For example, to retrieve a flowPackage containing values for attributes 11, 18 and 29, for a flow in RuleSet 7, with flow index 3447, one would GET the package whose Object Identifier (OID) is flowPackageData . 3.11.18.29 . 7. 0 . 3447 To get a package for the next such flow which had been active since time 12345 one would GETNEXT the package whose Object Identifier (OID) is flowPackageData . 3.11.18.29 . 7. 12345 . 3447" ::= { flowDataPackageEntry 5 } -- -- The Rule Table -- -- This is an array of RuleSets; the 'running' ones are indicated -- by the entries in the meter's flowManagerInfoTable. Several -- RuleSets can be held in a meter so that the manager can change the -- running RuleSets easily, for example with time of day. Note that -- a manager may not change the rules in any RuleSet currently -- referenced within the flowManagerInfoTable (either as 'current' or -- 'standby')! See the 'Traffic Flow Measurement: Architecture' -- document [RTFM-ARC] for details of rules and how they are used. -- Space for a RuleSet is allocated by setting the value of -- flowRuleInfoSize in the rule table's flowRuleSetInfoTable row. -- Values for each row in the RuleSet (Selector, Mask, MatchedValue, -- Action and Parameter) can then be set by the meter. -- Although an individual rule within a RuleSet could be modified, -- it is much safer to simply download a complete new RuleSet. flowRuleTable OBJECT-TYPE SYNTAX SEQUENCE OF FlowRuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Contains all the RuleSets which may be used by the meter." ::= { flowRules 1 } flowRuleEntry OBJECT-TYPE SYNTAX FlowRuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The rule record itself." INDEX { flowRuleSet, flowRuleIndex } ::= { flowRuleTable 1 } FlowRuleEntry ::= SEQUENCE { flowRuleSet Integer32, flowRuleIndex Integer32, flowRuleSelector RuleAttributeNumber, flowRuleMask RuleAddress, flowRuleMatchedValue RuleAddress, flowRuleAction ActionNumber, flowRuleParameter Integer32 } flowRuleSet OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Selects a RuleSet from the array of RuleSets." ::= { flowRuleEntry 1 } flowRuleIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index into the Rule table. N.B: These values will normally be consecutive, given the fall-through semantics of processing the table." ::= { flowRuleEntry 2 } flowRuleSelector OBJECT-TYPE SYNTAX RuleAttributeNumber MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the attribute to be matched. null(0) is a special case; null rules always succeed. matchingStoD(50) is set by the meter's Packet Matching Engine. Its value is true(1) if the PME is attempting to match the packet with its addresses in Source-to-Destination order (i.e. as they appear in the packet), and false(2) otherwise. Details of how packets are matched are given in the 'Traffic Flow Measurement: Architecture' document [RTFM-ARC]. v1(51), v2(52), v3(53), v4(54) and v5(55) select meter variables, each of which can hold the name (i.e. selector value) of an address attribute. When one of these is used as a selector, its value specifies the attribute to be tested. Variable values are set by an Assign action." ::= { flowRuleEntry 3 } flowRuleMask OBJECT-TYPE SYNTAX RuleAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The initial mask used to compute the desired value. If the mask is zero the rule's test will always succeed." ::= { flowRuleEntry 4 } flowRuleMatchedValue OBJECT-TYPE SYNTAX RuleAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The resulting value to be matched for equality. Specifically, if the attribute chosen by the flowRuleSelector logically ANDed with the mask specified by the flowRuleMask equals the value specified in the flowRuleMatchedValue, then continue processing the table entry based on the action specified by the flowRuleAction entry. Otherwise, proceed to the next entry in the rule table." ::= { flowRuleEntry 5 } flowRuleAction OBJECT-TYPE SYNTAX ActionNumber MAX-ACCESS read-write STATUS current DESCRIPTION "The action to be taken if this rule's test succeeds, or if the meter's 'test' flag is off. Actions are opcodes for the meter's Packet Matching Engine; details are given in the 'Traffic Flow Measurement: Architecture' document [RTFM-ARC]." ::= { flowRuleEntry 6 } flowRuleParameter OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "A parameter value providing extra information for this rule's action. Most of the actions use the parameter value to specify which rule to execute after this rule's test has failed; details are given in the 'Traffic Flow Measurement: Architecture' document [RTFM-ARC]." ::= { flowRuleEntry 7 } -- -- Traffic Flow Meter conformance statement -- flowMIBCompliances OBJECT IDENTIFIER ::= { flowMIBConformance 1 } flowMIBGroups OBJECT IDENTIFIER ::= { flowMIBConformance 2 } flowControlGroup OBJECT-GROUP OBJECTS { flowRuleInfoSize, flowRuleInfoOwner, flowRuleInfoTimeStamp, flowRuleInfoStatus, flowRuleInfoName, flowRuleInfoRulesReady, flowRuleInfoFlowRecords, flowInterfaceSampleRate, flowInterfaceLostPackets, flowReaderTimeout, flowReaderOwner, flowReaderLastTime, flowReaderPreviousTime, flowReaderStatus, flowReaderRuleSet, flowManagerCurrentRuleSet, flowManagerStandbyRuleSet, flowManagerHighWaterMark, flowManagerCounterWrap, flowManagerOwner, flowManagerTimeStamp, flowManagerStatus, flowManagerRunningStandby, flowFloodMark, flowInactivityTimeout, flowActiveFlows, flowMaxFlows, flowFloodMode } STATUS deprecated DESCRIPTION "The control group defines objects which are used to control an accounting meter." ::= {flowMIBGroups 1 } flowDataTableGroup OBJECT-GROUP OBJECTS { -- flowDataIndex, <- INDEX, not-accessible flowDataStatus, flowDataSourceInterface, flowDataSourceAdjacentType, flowDataSourceAdjacentAddress, flowDataSourceAdjacentMask, flowDataSourcePeerType, flowDataSourcePeerAddress, flowDataSourcePeerMask, flowDataSourceTransType, flowDataSourceTransAddress, flowDataSourceTransMask, flowDataDestInterface, flowDataDestAdjacentType, flowDataDestAdjacentAddress, flowDataDestAdjacentMask, flowDataDestPeerType, flowDataDestPeerAddress, flowDataDestPeerMask, flowDataDestTransType, flowDataDestTransAddress, flowDataDestTransMask, -- flowDataRuleSet, <- INDEX, not-accessible flowDataToOctets, flowDataToPDUs, flowDataFromOctets, flowDataFromPDUs, flowDataFirstTime, flowDataLastActiveTime, flowDataSourceClass, flowDataDestClass, flowDataClass, flowDataSourceKind, flowDataDestKind, flowDataKind } STATUS deprecated DESCRIPTION "The flow table group defines objects which provide the structure for the flow table, including the creation time and activity time indexes into it. In addition it defines objects which provide a base set of flow attributes for the adjacent, peer and transport layers, together with a flow's counters and times. Finally it defines a flow's class and kind attributes, which are set by rule actions." ::= {flowMIBGroups 2 } flowDataScaleGroup OBJECT-GROUP OBJECTS { flowManagerCounterWrap, flowDataPDUScale, flowDataOctetScale } STATUS deprecated DESCRIPTION "The flow scale group defines objects which specify scale factors for counters." ::= {flowMIBGroups 3 } flowDataSubscriberGroup OBJECT-GROUP OBJECTS { flowDataSourceSubscriberID, flowDataDestSubscriberID, flowDataSessionID } STATUS current DESCRIPTION "The flow subscriber group defines objects which may be used to identify the end point(s) of a flow." ::= {flowMIBGroups 4 } flowDataColumnTableGroup OBJECT-GROUP OBJECTS { flowColumnActivityAttribute, flowColumnActivityIndex, flowColumnActivityTime, flowColumnActivityData } STATUS deprecated DESCRIPTION "The flow column table group defines objects which can be used to collect part of a column of attribute values from the flow table." ::= {flowMIBGroups 5 } flowDataPackageGroup OBJECT-GROUP OBJECTS { flowPackageData } STATUS current DESCRIPTION "The data package group defines objects which can be used to collect a specified set of attribute values from a row of the flow table." ::= {flowMIBGroups 6 } flowRuleTableGroup OBJECT-GROUP OBJECTS { flowRuleSelector, flowRuleMask, flowRuleMatchedValue, flowRuleAction, flowRuleParameter } STATUS current DESCRIPTION "The rule table group defines objects which hold the set(s) of rules specifying which traffic flows are to be accounted for." ::= {flowMIBGroups 7 } flowDataScaleGroup2 OBJECT-GROUP OBJECTS { -- flowManagerCounterWrap, <- Deprecated flowDataPDUScale, flowDataOctetScale } STATUS current DESCRIPTION "The flow scale group defines objects which specify scale factors for counters. This group replaces the earlier version of flowDataScaleGroup above (now deprecated)." ::= {flowMIBGroups 8} flowControlGroup2 OBJECT-GROUP OBJECTS { flowRuleInfoSize, flowRuleInfoOwner, flowRuleInfoTimeStamp, flowRuleInfoStatus, flowRuleInfoName, -- flowRuleInfoRulesReady, <- Deprecated flowRuleInfoFlowRecords, flowInterfaceSampleRate, flowInterfaceLostPackets, flowReaderTimeout, flowReaderOwner, flowReaderLastTime, flowReaderPreviousTime, flowReaderStatus, flowReaderRuleSet, flowManagerCurrentRuleSet, flowManagerStandbyRuleSet, flowManagerHighWaterMark, -- flowManagerCounterWrap, <- Moved to DataScaleGroup flowManagerOwner, flowManagerTimeStamp, flowManagerStatus, flowManagerRunningStandby, flowFloodMark, flowInactivityTimeout, flowActiveFlows, flowMaxFlows, flowFloodMode } STATUS current DESCRIPTION "The control group defines objects which are used to control an accounting meter. It replaces the earlier version of flowControlGroup above (now deprecated)." ::= {flowMIBGroups 9 } flowMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for a Traffic Flow Meter." MODULE MANDATORY-GROUPS { flowControlGroup2, flowDataTableGroup, flowDataPackageGroup, flowRuleTableGroup } ::= { flowMIBCompliances 1 } END